Describe the bug
Beim Abfragen eines ABB B23 113 100 Zählers wird ein Datenpunkt "mbus.0.ABB-1478077.data.11-More records follow" angelegt.
Screenshots & Logfiles
2022-06-29 12:58:07.867 - �[32minfo�[39m: smartmeter.0 (253) Received 10 values, 3 updated
2022-06-29 12:58:39.863 - �[32minfo�[39m: host.DiskStation-001 "system.adapter.mbus.0" enabled
2022-06-29 12:58:40.022 - �[32minfo�[39m: host.DiskStation-001 instance system.adapter.mbus.0 started with pid 5565
2022-06-29 12:58:41.506 - �[34mdebug�[39m: mbus.0 (5565) Redis Objects: Use Redis connection: 127.0.0.1:9001
2022-06-29 12:58:41.558 - �[34mdebug�[39m: mbus.0 (5565) Objects client ready ... initialize now
2022-06-29 12:58:41.571 - �[34mdebug�[39m: mbus.0 (5565) Objects create System PubSub Client
2022-06-29 12:58:41.572 - �[34mdebug�[39m: mbus.0 (5565) Objects create User PubSub Client
2022-06-29 12:58:41.592 - �[34mdebug�[39m: mbus.0 (5565) Objects client initialize lua scripts
2022-06-29 12:58:41.600 - �[34mdebug�[39m: mbus.0 (5565) Objects connected to redis: 127.0.0.1:9001
2022-06-29 12:58:41.619 - �[34mdebug�[39m: mbus.0 (5565) Redis States: Use Redis connection: 127.0.0.1:9000
2022-06-29 12:58:41.628 - �[34mdebug�[39m: mbus.0 (5565) States create System PubSub Client
2022-06-29 12:58:41.630 - �[34mdebug�[39m: mbus.0 (5565) States create User PubSub Client
2022-06-29 12:58:41.680 - �[34mdebug�[39m: mbus.0 (5565) States connected to redis: 127.0.0.1:9000
2022-06-29 12:58:41.726 - �[34mdebug�[39m: mbus.0 (5565) Plugin sentry Initialize Plugin (enabled=true)
2022-06-29 12:58:42.107 - �[32minfo�[39m: mbus.0 (5565) starting. Version 2.3.4 in /opt/iobroker/node_modules/iobroker.mbus, node: v14.19.2, js-controller: 4.0.23
2022-06-29 12:58:42.135 - �[32minfo�[39m: mbus.0 (5565) Default Update Interval: 2400
2022-06-29 12:58:42.136 - �[32minfo�[39m: mbus.0 (5565) Initialize M-Bus Serial to /dev/mbus with 115200baud
2022-06-29 12:58:42.147 - �[32minfo�[39m: mbus.0 (5565) Schedule initialization for M-Bus-ID 0147807742042002 with update interval 120
2022-06-29 12:58:42.245 - �[34mdebug�[39m: mbus.0 (5565) connected set to true
2022-06-29 12:58:42.247 - �[34mdebug�[39m: mbus.0 (5565) connected set to true
2022-06-29 12:58:42.649 - �[34mdebug�[39m: mbus.0 (5565) Process: 0147807742042002
2022-06-29 12:58:46.101 - �[34mdebug�[39m: mbus.0 (5565) M-Bus ID 0147807742042002 data: {
"SlaveInformation": {
"Id": 1478077,
"Manufacturer": "ABB",
"Version": 32,
"ProductName": "",
"Medium": "Electricity",
"AccessNumber": 52,
"Status": 0,
"Signature": 0
},
"DataRecord": [
{
"id": 0,
"frame": 0,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Energy (10 Wh)",
"Value": 0,
"Timestamp": "2022-06-29T10:58:44Z"
},
{
"id": 1,
"frame": 0,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Manufacturer specific",
"Value": 0,
"Timestamp": "2022-06-29T10:58:44Z"
},
{
"id": 2,
"frame": 0,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Manufacturer specific",
"Value": 0,
"Timestamp": "2022-06-29T10:58:44Z"
},
{
"id": 3,
"frame": 0,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Manufacturer specific",
"Value": 0,
"Timestamp": "2022-06-29T10:58:44Z"
},
{
"id": 4,
"frame": 0,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Manufacturer specific",
"Value": 0,
"Timestamp": "2022-06-29T10:58:44Z"
},
{
"id": 5,
"frame": 0,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Manufacturer specific",
"Value": 0,
"Timestamp": "2022-06-29T10:58:44Z"
},
{
"id": 6,
"frame": 0,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Manufacturer specific",
"Value": 0,
"Timestamp": "2022-06-29T10:58:44Z"
},
{
"id": 7,
"frame": 0,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Manufacturer specific",
"Value": 0,
"Timestamp": "2022-06-29T10:58:44Z"
},
{
"id": 8,
"frame": 0,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Manufacturer specific",
"Value": 0,
"Timestamp": "2022-06-29T10:58:44Z"
},
{
"id": 9,
"frame": 0,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Firmware version",
"Value": "B1.50.0",
"Timestamp": "2022-06-29T10:58:44Z"
},
{
"id": 10,
"frame": 0,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Manufacturer specific",
"Value": "B23 113-100",
"Timestamp": "2022-06-29T10:58:44Z"
},
{
"id": 11,
"frame": 0,
"Function": "More records follow",
"Value": "",
"Timestamp": "2022-06-29T10:58:44Z"
},
{
"id": 12,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Power (1e-2 W)",
"Value": 0,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 13,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Power (1e-2 W)",
"Value": 0,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 14,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Power (1e-2 W)",
"Value": 0,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 15,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Power (1e-2 W)",
"Value": 0,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 16,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "1e-1 V",
"Value": 2366,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 17,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "1e-1 V",
"Value": 2369,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 18,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "1e-1 V",
"Value": 2358,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 19,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "1e-1 V",
"Value": 4105,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 20,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "1e-1 V",
"Value": 4101,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 21,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "1e-1 V",
"Value": 4079,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 22,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "m A",
"Value": 0,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 23,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "m A",
"Value": 0,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 24,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "m A",
"Value": 0,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 25,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Manufacturer specific",
"Value": 5004,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 26,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Manufacturer specific",
"Value": 0,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 27,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Manufacturer specific",
"Value": 3,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 28,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Tariff": 0,
"Device": 1,
"Unit": "Digital output (binary)",
"Value": 0,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 29,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Energy (10 Wh)",
"Value": 0,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 30,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Energy (10 Wh)",
"Value": 0,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 31,
"frame": 1,
"Function": "Instantaneous value",
"StorageNumber": 0,
"Unit": "Energy (10 Wh)",
"Value": 0,
"Timestamp": "2022-06-29T10:58:45Z"
},
{
"id": 32,
"frame": 1,
"Function": "Manufacturer specific",
"Value": "",
"Timestamp": "2022-06-29T10:58:45Z"
}
]
}
2022-06-29 12:58:46.116 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.info.Id
2022-06-29 12:58:46.120 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.info.Manufacturer
2022-06-29 12:58:46.124 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.info.Version
2022-06-29 12:58:46.127 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.info.ProductName
2022-06-29 12:58:46.131 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.info.Medium
2022-06-29 12:58:46.136 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.info.AccessNumber
2022-06-29 12:58:46.139 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.info.Status
2022-06-29 12:58:46.142 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.info.Signature
2022-06-29 12:58:46.144 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.info.address
2022-06-29 12:58:46.147 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.0-0-Current
2022-06-29 12:58:46.151 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.1-0-Current
2022-06-29 12:58:46.154 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.2-0-Current
2022-06-29 12:58:46.158 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.3-0-Current
2022-06-29 12:58:46.161 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.4-0-Current
2022-06-29 12:58:46.164 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.5-0-Current
2022-06-29 12:58:46.167 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.6-0-Current
2022-06-29 12:58:46.172 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.7-0-Current
2022-06-29 12:58:46.174 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.8-0-Current
2022-06-29 12:58:46.176 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.9-0-Current
2022-06-29 12:58:46.179 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.10-0-Current
2022-06-29 12:58:46.182 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.11-More records follow
2022-06-29 12:58:46.185 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.12-0-Current
2022-06-29 12:58:46.189 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.13-0-Current
2022-06-29 12:58:46.193 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.14-0-Current
2022-06-29 12:58:46.196 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.15-0-Current
2022-06-29 12:58:46.199 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.16-0-Current
2022-06-29 12:58:46.203 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.17-0-Current
2022-06-29 12:58:46.207 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.18-0-Current
2022-06-29 12:58:46.210 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.19-0-Current
2022-06-29 12:58:46.213 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.20-0-Current
2022-06-29 12:58:46.216 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.21-0-Current
2022-06-29 12:58:46.220 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.22-0-Current
2022-06-29 12:58:46.223 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.23-0-Current
2022-06-29 12:58:46.227 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.24-0-Current
2022-06-29 12:58:46.230 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.25-0-Current
2022-06-29 12:58:46.233 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.26-0-Current
2022-06-29 12:58:46.236 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.27-0-Current
2022-06-29 12:58:46.240 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.28-0-Current
2022-06-29 12:58:46.244 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.29-0-Current
2022-06-29 12:58:46.247 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.30-0-Current
2022-06-29 12:58:46.251 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.31-0-Current
2022-06-29 12:58:46.255 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.32
2022-06-29 12:58:46.258 - �[34mdebug�[39m: mbus.0 (5565) Create State ABB-1478077.data.lastStatus
2022-06-29 12:58:46.263 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.0-0-Current: 0 (unit: 10 Wh) with factor 0.01
2022-06-29 12:58:46.264 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.1-0-Current: 0 (unit: Manufacturer specific) with factor 0
2022-06-29 12:58:46.265 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.2-0-Current: 0 (unit: Manufacturer specific) with factor 0
2022-06-29 12:58:46.265 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.3-0-Current: 0 (unit: Manufacturer specific) with factor 0
2022-06-29 12:58:46.265 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.4-0-Current: 0 (unit: Manufacturer specific) with factor 0
2022-06-29 12:58:46.266 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.5-0-Current: 0 (unit: Manufacturer specific) with factor 0
2022-06-29 12:58:46.267 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.6-0-Current: 0 (unit: Manufacturer specific) with factor 0
2022-06-29 12:58:46.267 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.7-0-Current: 0 (unit: Manufacturer specific) with factor 0
2022-06-29 12:58:46.268 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.8-0-Current: 0 (unit: Manufacturer specific) with factor 0
2022-06-29 12:58:46.268 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.9-0-Current: B1.50.0 (unit: Firmware version) with factor 0
2022-06-29 12:58:46.268 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.10-0-Current: B23 113-100 (unit: Manufacturer specific) with factor 0
2022-06-29 12:58:46.269 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.11-More records follow: (unit: ) with factor 0
2022-06-29 12:58:46.269 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.12-0-Current: 0 (unit: 1e-2 W) with factor 0.01
2022-06-29 12:58:46.270 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.13-0-Current: 0 (unit: 1e-2 W) with factor 0.01
2022-06-29 12:58:46.270 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.14-0-Current: 0 (unit: 1e-2 W) with factor 0.01
2022-06-29 12:58:46.270 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.15-0-Current: 0 (unit: 1e-2 W) with factor 0.01
2022-06-29 12:58:46.271 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.16-0-Current: 2366 (unit: 1e-1 V) with factor 0.1
2022-06-29 12:58:46.271 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.17-0-Current: 2369 (unit: 1e-1 V) with factor 0.1
2022-06-29 12:58:46.272 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.18-0-Current: 2358 (unit: 1e-1 V) with factor 0.1
2022-06-29 12:58:46.272 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.19-0-Current: 4105 (unit: 1e-1 V) with factor 0.1
2022-06-29 12:58:46.272 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.20-0-Current: 4101 (unit: 1e-1 V) with factor 0.1
2022-06-29 12:58:46.273 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.21-0-Current: 4079 (unit: 1e-1 V) with factor 0.1
2022-06-29 12:58:46.273 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.22-0-Current: 0 (unit: m A) with factor 0.001
2022-06-29 12:58:46.274 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.23-0-Current: 0 (unit: m A) with factor 0.001
2022-06-29 12:58:46.274 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.24-0-Current: 0 (unit: m A) with factor 0.001
2022-06-29 12:58:46.274 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.25-0-Current: 5004 (unit: Manufacturer specific) with factor 0
2022-06-29 12:58:46.275 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.26-0-Current: 0 (unit: Manufacturer specific) with factor 0
2022-06-29 12:58:46.275 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.27-0-Current: 3 (unit: Manufacturer specific) with factor 0
2022-06-29 12:58:46.276 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.28-0-Current: 0 (unit: binary) with factor 0
2022-06-29 12:58:46.276 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.29-0-Current: 0 (unit: 10 Wh) with factor 0.01
2022-06-29 12:58:46.276 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.30-0-Current: 0 (unit: 10 Wh) with factor 0.01
2022-06-29 12:58:46.277 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.31-0-Current: 0 (unit: 10 Wh) with factor 0.01
2022-06-29 12:58:46.277 - �[34mdebug�[39m: mbus.0 (5565) Value ABB-1478077.data.32: (unit: ) with factor 0
Versions:
- Adapter version: 2.3.4
- JS-Controller version: 4.0.23
- Node version: v14.19.2
- Operating system: Linux (Synology Docker Container)