Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathcheckOptionsBAAM.m
210 lines (193 loc) · 9.56 KB
/
checkOptionsBAAM.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
%
% University of Alberta, Edmonton, Canada
% Laboratory of Advanced Separation Processes (Prof. Dr. Arvind Rajendran)
%
% Project: ........
% Year: 2019
% MATLAB: R2018b, Windows 64bit
% Authors: Vishal Subramanian Balashankar (VS)
% Ashwin Kumar Rajagopalan (AK)
%
% Purpose:
% This function performs a sanity check on the inputs provided by the user
% for the simulation info and the adsorbent info. If there is a serious
% issue this function throws out an error and stops the execution of the
% program. If it is something minor like a variable not entered, certain
% default value will be put into the missing entry and the model would be
% simulated. In such a case there would be a warning that would be thrown
% out by the function
%
% Last modified:
% - 2019-01-25, AK: Added more options that needs to be checked if they
% fall within the range or if they are empty
% - 2019-01-24, AK: Introduced header for this file
%
% Input arguments:
% - simInfo: Structure containing information for the simulation.
% These generally do not depend on the adsorbent. This
% contains pressure values, temperature, column
% properties, etc.,
% - adsInfo: Structure containing information about the adsorbent.
% This contains the adsorbent name, adsorbent density and
% DSL parameters for component A and B. In the original
% manuscript A is CO2 and B is N2.
%
% Output arguments:
% - simInfo: Structure containing information for the simulation.
% These generally do not depend on the adsorbent. This
% contains pressure values, temperature, column
% properties, etc.,
% - adsInfo: Structure containing information about the adsorbent.
% This contains the adsorbent name, adsorbent density and
% DSL parameters for component A and B. In the original
% manuscript A is CO2 and B is N2.
% Note that the output arguments can either be the same as the input
% arguments or could have been altered by this function based on certain
% checks that are put in place.
%
% %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
function [simInfo,adsInfo] = checkOptionsBAAM(simInfo,adsInfo)
% Check if flag for loading adsorbent is empty. If it is empty, then user
% input/default will be used for simulations
if simInfo.loadAdsorbentInfo == 0
simInfo.filenameAdsorbentInfo = [];
warning('BAAM:checkOptionsBAAM:loadadsorbentinfo',...
'The variable loadAdsorbentInfo is empty. Will load user data or default settings to run the BAAM model!');
end
% Check if mole fraction of component A is empty or if it is above 1 or
% below 0
if isempty(simInfo.molFracFeed_A)
simInfo.molFracFeed_A = 0.15;
warning('BAAM:checkOptionsBAAM:molefractionfeed',...
'The variable molFracFeed_A is empty. Mole fraction of 0.15 has been set for component A in feed!');
end
if simInfo.molFracFeed_A < 0 || simInfo.molFracFeed_A > 1
error('BAAM:checkOptionsBAAM:molefractionfeed',...
'The variable voidFraction is either below 0 or above 1. Check it!');
end
% Check if molarMass_A of component A is empty
if isempty(simInfo.molarMass_A)
simInfo.molarMass_A = 44.01;
warning('BAAM:checkOptionsBAAM:molarmass',...
'The variable molarMass_A is empty. Molar mass of component A has been set to 44.01 (CO2)!');
end
% Check if temperature is empty
if isempty(simInfo.temperature)
simInfo.temperature = 298.15;
warning('BAAM:checkOptionsBAAM:molarmass',...
'The variable temperature is empty. The feed temperature has been set to 298.15 K!');
end
% Check if pressureHigh is empty
if isempty(simInfo.pressureHigh)
simInfo.pressureHigh = 1;
warning('BAAM:checkOptionsBAAM:highpressure',...
'The variable pressureHigh is empty. The high pressure has been set to 1 bar!');
end
% Check if pressureLow is empty
if isempty(simInfo.pressureLow)
simInfo.pressureLow = 0.03;
warning('BAAM:checkOptionsBAAM:lowpressure',...
'The variable pressureLow is empty. The low pressure has been set to 0.03 bar!');
end
% Check if pressureHigh is greater than pressureLow
if simInfo.pressureHigh < simInfo.pressureLow
error('BAAM:checkOptionsBAAM:highpressureless',...
'The variable pressureLow should be smaller than pressureHigh. Check it!');
end
% Check if pressureLowUpperBound is empty
if isempty(simInfo.pressureLowUpperBound)
simInfo.pressureLowUpperBound = 0.10;
warning('BAAM:checkOptionsBAAM:lowpressureupperbound',...
'The variable pressureLowUpperBound is empty. The low pressure upper bound for BAAM has been set to 0.10 bar!');
end
if simInfo.pressureLowUpperBound < simInfo.pressureLow ...
|| simInfo.pressureLowUpperBound > simInfo.pressureHigh
error('BAAM:checkOptionsBAAM:lowpressureupperbound',...
'The variable pressureLowUpperBound is either below low pressure or above high pressure. Check it!');
end
% Check if void fraction is empty or if it is above 1 or below 0
if isempty(simInfo.voidFraction)
simInfo.voidFraction = 0.37;
warning('BAAM:checkOptionsBAAM:voidfraction',...
'The variable voidFraction is empty. The void fraction has been set to 0.37!');
end
if simInfo.voidFraction < 0 || simInfo.voidFraction > 1
error('BAAM:checkOptionsBAAM:voidfraction',...
'The variable voidFraction is either below 0 or above 1. Check it!');
end
% Check if adiabatic constant of the gas is empty or if it is below 1
if isempty(simInfo.adiabaticConstant)
simInfo.adiabaticConstant = 1.4;
warning('BAAM:checkOptionsBAAM:adiabaticconstant',...
'The variable adiabaticConstant is empty. The adiabatic constant has been set to 1.4!');
end
if simInfo.adiabaticConstant < 1
error('BAAM:checkOptionsBAAM:adiabaticconstant',...
'The variable voidFraction is either below 1. For an ideal gas it should be above 1. Check it!');
end
% Check if the pump efficiency is empty or if it is above 1 or below 0
if isempty(simInfo.pumpEfficiency)
simInfo.pumpEfficiency = 0.72;
warning('BAAM:checkOptionsBAAM:pumpefficiency',...
'The variable pumpEfficiency is empty. The vacuum pump efficiency has been set to 0.72!');
end
if simInfo.pumpEfficiency < 0 || simInfo.pumpEfficiency > 1
error('BAAM:checkOptionsBAAM:pumpefficiency',...
'The variable pumpEfficiency is either below 0 or above 1. Check it!');
end
% Check if the flag for plotting is empty. If the adsorbent info is input
% by the user then plot the figure at the end of the simulation if not turn
% off the plotting functionality.
if isempty(simInfo.plotFlag)
if simInfo.loadAdsorbentInfo
simInfo.plotFlag = false;
warning('BAAM:checkOptionsBAAM:plotflag',...
'The variable plotFlag is empty. Plotting has been turned off!');
else
simInfo.plotFlag = true;
warning('BAAM:checkOptionsBAAM:plotflag',...
'The variable plotFlag is empty. Plotting has been turned off!');
end
end
% Check if the mole fraction variable for plotting is empty.
if isnan(simInfo.molFracPlotting)
simInfo.molFracPlotting = [0.15,0.30,0.50,0.75,0.9,1.0];
warning('BAAM:checkOptionsBAAM:molfracplotting',...
'The variable molFracPlotting is empty. The final plot would be generated at 6 different default mole fractions!');
end
% Check if the isotherm parameters for component A and site 1 is empty
if isempty(adsInfo.qSaturationSite1_A) || isempty(adsInfo.adsorptionCoefficientSite1_A)...
|| isempty(adsInfo.internalEnergySite1_A)
error('BAAM:checkOptionsBAAM:isothermcompAsite1',...
'Some or all the isotherm parameters for component A and site 1 is empty. Check it!');
end
% Check if the isotherm parameters for component B and site 1 is empty
if isempty(adsInfo.qSaturationSite1_B) || isempty(adsInfo.adsorptionCoefficientSite1_B)...
|| isempty(adsInfo.internalEnergySite1_B)
error('BAAM:checkOptionsBAAM:isothermcompBsite1',...
'Some or all the isotherm parameters for component B and site 1 is empty. Check it!');
end
% Check if the isotherm parameters for component A and site 2 is empty or
% zero. Set the default value to 0 for all the parameters in this case.
if isempty(adsInfo.qSaturationSite2_A) || isempty(adsInfo.adsorptionCoefficientSite2_A)...
|| isempty(adsInfo.internalEnergySite2_A) || adsInfo.qSaturationSite2_A == 0 ...
|| adsInfo.adsorptionCoefficientSite2_A == 0|| adsInfo.internalEnergySite2_A == 0
warning('BAAM:checkOptionsBAAM:isothermcompAsite2',...
'Some or all the isotherm parameters for component A and site 2 is empty or zero. All the parameters set to zero!');
adsInfo.qSaturationSite2_A = 0;
adsInfo.adsorptionCoefficientSite2_A = 0;
adsInfo.internalEnergySite2_A = 0;
end
% Check if the isotherm parameters for component B and site 2 is empty or
% zero. Set the default value to 0 for all the parameters in this case.
if isempty(adsInfo.qSaturationSite2_B) || isempty(adsInfo.adsorptionCoefficientSite2_B)...
|| isempty(adsInfo.internalEnergySite2_B) || adsInfo.qSaturationSite2_B == 0 ...
|| adsInfo.adsorptionCoefficientSite2_B == 0|| adsInfo.internalEnergySite2_B == 0
warning('BAAM:checkOptionsBAAM:isothermcompBsite2',...
'Some or all the isotherm parameters for component B and site 2 is empty or zero. All the parameters set to zero!');
adsInfo.qSaturationSite2_B = 0;
adsInfo.adsorptionCoefficientSite2_B = 0;
adsInfo.internalEnergySite2_B = 0;
end
end