Skip to content

Commit f9d0c1c

Browse files
committed
2 parents 3fe7c4e + 897fc45 commit f9d0c1c

File tree

1 file changed

+4
-6
lines changed

1 file changed

+4
-6
lines changed

_pages/researchprojects.md

Lines changed: 4 additions & 6 deletions
Original file line numberDiff line numberDiff line change
@@ -37,6 +37,7 @@ For the research on patients with transplanted kidneys, our group has presented
3737
![HP Kidney 2](../assets/images/research_projects/hp_kidney2.png)
3838

3939
1. Tang S, Meng M V., Slater JB, et al. Metabolic imaging with hyperpolarized 13C pyruvate magnetic resonance imaging in patients with renal tumors—Initial experience. Cancer. 2021;127(15):2693-2704. doi:10.1002/cncr.33554
40+
2. Liu X, Lai YC, Cui D, et al. Initial experience of metabolic imaging with hyperpolarized [1‐13C] pyruvate MRI in kidney transplant patients. Journal of Magnetic Resonance Imaging. 2025 Apr;61(4):1969-78. doi: 10.1002/jmri.29580
4041

4142
### Hyperpolarized Carbon-13 MRI: Cardiac Studies
4243

@@ -66,12 +67,9 @@ Illustration of the iterative motion-compensation (iMoCo) reconstruction for UTE
6667
![Lung MRI 2](../assets/images/research_projects/lung_mri_2.jpg)
6768
Motion-compensated low-rank (MoCoLoR) reconstructions of UTE Lung MRI data across a range of patient research subjects with various ages, body sizes, and pathologies [3].
6869

69-
1. Jiang, Wenwen, Frank Ong, Kevin M Johnson, Scott K Nagle, Thomas A Hope, Michael Lustig, and Peder E.Z. Larson. “Motion Robust High Resolution 3D Free-Breathing Pulmonary MRI Using Dynamic 3D Image Self-Navigator.” Magnetic Resonance in Medicine, n.d., n/a-n/a. <https://doi.org/10.1002/mrm.26958>
70-
<https://github.com/PulmonaryMRI/pulmonary-MRI-reconstruction>
71-
2. Zhu, Xucheng, Marilynn Chan, Michael Lustig, Kevin M. Johnson, and Peder E. Z. Larson. “Iterative Motion-Compensation Reconstruction Ultra-Short TE (iMoCo UTE) for High-Resolution Free-Breathing Pulmonary MRI.” Magnetic Resonance in Medicine 83, no. 4 (2020): 1208–21. <https://doi.org/10.1002/mrm.27998>
72-
<https://github.com/PulmonaryMRI/imoco_recon>
73-
3. Tan, Fei, Xucheng Zhu, Marilynn Chan, Matthew A. Zapala, Shreyas S. Vasanawala, Frank Ong, Michael Lustig, and Peder E. Z. Larson. “Motion-Compensated Low-Rank Reconstruction for Simultaneous Structural and Functional UTE Lung MRI.” Magnetic Resonance in Medicine 90, no. 3 (2023): 1101–13. <https://doi.org/10.1002/mrm.29703>
74-
<https://github.com/PulmonaryMRI/MoCoLoR>
70+
1. Jiang, Wenwen, Frank Ong, Kevin M Johnson, Scott K Nagle, Thomas A Hope, Michael Lustig, and Peder E.Z. Larson. “Motion Robust High Resolution 3D Free-Breathing Pulmonary MRI Using Dynamic 3D Image Self-Navigator.” Magnetic Resonance in Medicine, n.d., n/a-n/a. <https://doi.org/10.1002/mrm.26958> <https://github.com/PulmonaryMRI/pulmonary-MRI-reconstruction>
71+
2. Zhu, Xucheng, Marilynn Chan, Michael Lustig, Kevin M. Johnson, and Peder E. Z. Larson. “Iterative Motion-Compensation Reconstruction Ultra-Short TE (iMoCo UTE) for High-Resolution Free-Breathing Pulmonary MRI.” Magnetic Resonance in Medicine 83, no. 4 (2020): 1208–21. <https://doi.org/10.1002/mrm.27998> <https://github.com/PulmonaryMRI/imoco_recon>
72+
3. Tan, Fei, Xucheng Zhu, Marilynn Chan, Matthew A. Zapala, Shreyas S. Vasanawala, Frank Ong, Michael Lustig, and Peder E. Z. Larson. “Motion-Compensated Low-Rank Reconstruction for Simultaneous Structural and Functional UTE Lung MRI.” Magnetic Resonance in Medicine 90, no. 3 (2023): 1101–13. <https://doi.org/10.1002/mrm.29703> <https://github.com/PulmonaryMRI/MoCoLoR>
7573

7674
### Myelin Imaging by UTE MRI
7775

0 commit comments

Comments
 (0)