diff --git a/docs/release_notes.rst b/docs/release_notes.rst index 5032ba11..5e7d83b0 100644 --- a/docs/release_notes.rst +++ b/docs/release_notes.rst @@ -24,6 +24,8 @@ Upcoming Release * Align `snakemake` version and the related `mock_snakemake` to PyPSA-Eur (https://github.com/PyPSA/technology-data/pull/177) +* Improve assumptions for iron-air batteries (https://github.com/PyPSA/technology-data/pull/179) + * Improve filename consistency in the sources (https://github.com/PyPSA/technology-data/pull/178) * Include further unit tests for compile_cost_assumptions_usa.py (https://github.com/PyPSA/technology-data/pull/182) diff --git a/inputs/US/manual_input_usa.csv b/inputs/US/manual_input_usa.csv index 04ef000d..d7da3d60 100644 --- a/inputs/US/manual_input_usa.csv +++ b/inputs/US/manual_input_usa.csv @@ -127,4 +127,8 @@ Solid biomass steam reforming,FOM,2020,0.05,%/year,2010,"JRC, 01_JRC-EU-TIMES Fu Natural gas steam reforming CC,FOM,2030,0.05,%/year,2010,"JRC, 01_JRC-EU-TIMES Full model ", Natural gas steam reforming CC,FOM,2050,0.05,%/year,2010,"JRC, 01_JRC-EU-TIMES Full model ", Coal gasification CC,FOM,2030,0.07,%/year,2010,"JRC, 01_JRC-EU-TIMES Full model ", -Biomass gasification CC,FOM,2030,0.02,%/year,2010,"JRC, 01_JRC-EU-TIMES Full model ", \ No newline at end of file +Biomass gasification CC,FOM,2030,0.02,%/year,2010,"JRC, 01_JRC-EU-TIMES Full model ", +iron-air battery,investment,2025,28.62,EUR/kWh,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery,investment,2030,19.05,EUR/kWh,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery,investment,2035,14.40,EUR/kWh,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery,investment,2040,12.69,EUR/kWh,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", \ No newline at end of file diff --git a/inputs/manual_input.csv b/inputs/manual_input.csv index 54f9f86e..b9f1ce5a 100644 --- a/inputs/manual_input.csv +++ b/inputs/manual_input.csv @@ -387,20 +387,20 @@ allam,investment,2030,1500,EUR/kW,2020,Own assumption. TODO: Find better technol allam,VOM,2030,2,EUR/MWh,2020,Own assumption. TODO: Find better technology data and cost assumptions, allam,efficiency,2030,0.6,p.u.,2020,Own assumption. TODO: Find better technology data and cost assumptions, allam,lifetime,2030,30,years,2020,Own assumption. TODO: Find better technology data and cost assumptions, -iron-air battery,FOM,2025,1.02185373078457,%/year,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", -iron-air battery,FOM,2030,1,%/year,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", -iron-air battery,FOM,2035,1.10628646943421,%/year,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", -iron-air battery,FOM,2040,1.1807773334732,%/year,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", -iron-air battery,investment,2025,23.45,EUR/kWh,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", -iron-air battery,investment,2030,15.61,EUR/kWh,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", -iron-air battery,investment,2035,11.79,EUR/kWh,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", -iron-air battery,investment,2040,10.4,EUR/kWh,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", -iron-air battery charge,efficiency,2025,0.7,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", -iron-air battery charge,efficiency,2030,0.71,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", -iron-air battery charge,efficiency,2035,0.73,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", -iron-air battery charge,efficiency,2040,0.74,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", -iron-air battery discharge,efficiency,2025,0.59,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", -iron-air battery discharge,efficiency,2030,0.6,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", -iron-air battery discharge,efficiency,2035,0.62,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", -iron-air battery discharge,efficiency,2040,0.63,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", -iron-air battery,lifetime,2030,17.5,years,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery,FOM,2025,1.02185373078457,%/year,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery,FOM,2030,1,%/year,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery,FOM,2035,1.10628646943421,%/year,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery,FOM,2040,1.1807773334732,%/year,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery,investment,2025,30.05,EUR/kWh,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery,investment,2030,20.00,EUR/kWh,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery,investment,2035,15.11,EUR/kWh,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery,investment,2040,13.33,EUR/kWh,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery charge,efficiency,2025,0.70,per unit,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery charge,efficiency,2030,0.71,per unit,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery charge,efficiency,2035,0.73,per unit,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery charge,efficiency,2040,0.74,per unit,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery discharge,efficiency,2025,0.59,per unit,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery discharge,efficiency,2030,0.60,per unit,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery discharge,efficiency,2035,0.62,per unit,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery discharge,efficiency,2040,0.63,per unit,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", +iron-air battery,lifetime,2030,17.5,years,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4", diff --git a/outputs/US/costs_2020.csv b/outputs/US/costs_2020.csv index 29bc21cf..db60820a 100644 --- a/outputs/US/costs_2020.csv +++ b/outputs/US/costs_2020.csv @@ -3948,11 +3948,11 @@ industrial heat pump medium temperature,efficiency,2.55,per unit,"Danish Energy industrial heat pump medium temperature,investment,877.2984,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0,, industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0,, iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0,, -iron-air battery,FOM,1.0219,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery,investment,23.45,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery charge,efficiency,0.7,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery discharge,efficiency,0.59,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, +iron-air battery,FOM,1.0219,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery,investment,23.9381,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery charge,efficiency,0.7,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery discharge,efficiency,0.59,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,,,, lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,, lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,, diff --git a/outputs/US/costs_2025.csv b/outputs/US/costs_2025.csv index 7c54cf8a..7c7852d3 100644 --- a/outputs/US/costs_2025.csv +++ b/outputs/US/costs_2025.csv @@ -4034,11 +4034,11 @@ industrial heat pump medium temperature,efficiency,2.625,per unit,"Danish Energy industrial heat pump medium temperature,investment,830.775,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0,, industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0,, iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0,, -iron-air battery,FOM,1.0219,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery,investment,23.45,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery charge,efficiency,0.7,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery discharge,efficiency,0.59,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, +iron-air battery,FOM,1.0219,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery,investment,23.9381,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery charge,efficiency,0.7,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery discharge,efficiency,0.59,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,,,, lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,, lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,, diff --git a/outputs/US/costs_2030.csv b/outputs/US/costs_2030.csv index 1de19604..fec92214 100644 --- a/outputs/US/costs_2030.csv +++ b/outputs/US/costs_2030.csv @@ -4190,11 +4190,11 @@ industrial heat pump medium temperature,efficiency,2.7,per unit,"Danish Energy A industrial heat pump medium temperature,investment,784.2516,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0,, industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0,, iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0,, -iron-air battery,FOM,1.0,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery,investment,15.61,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery charge,efficiency,0.71,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery discharge,efficiency,0.6,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, +iron-air battery,FOM,1.0,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery,investment,15.9337,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery charge,efficiency,0.71,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery discharge,efficiency,0.6,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,,,, lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,, lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,, diff --git a/outputs/US/costs_2035.csv b/outputs/US/costs_2035.csv index 02bc6ae2..a0966d1f 100644 --- a/outputs/US/costs_2035.csv +++ b/outputs/US/costs_2035.csv @@ -4214,11 +4214,11 @@ industrial heat pump medium temperature,efficiency,2.75,per unit,"Danish Energy industrial heat pump medium temperature,investment,759.6808,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0,, industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0,, iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0,, -iron-air battery,FOM,1.1063,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery,investment,11.79,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery charge,efficiency,0.73,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery discharge,efficiency,0.62,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, +iron-air battery,FOM,1.1063,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery,investment,12.0443,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery charge,efficiency,0.73,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery discharge,efficiency,0.62,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,,,, lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,, lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,, diff --git a/outputs/US/costs_2040.csv b/outputs/US/costs_2040.csv index b6e1bb20..5c32ba14 100644 --- a/outputs/US/costs_2040.csv +++ b/outputs/US/costs_2040.csv @@ -4214,11 +4214,11 @@ industrial heat pump medium temperature,efficiency,2.8,per unit,"Danish Energy A industrial heat pump medium temperature,investment,735.11,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0,, industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0,, iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0,, -iron-air battery,FOM,1.1808,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery,investment,10.4,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery charge,efficiency,0.74,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery discharge,efficiency,0.63,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, +iron-air battery,FOM,1.1808,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery,investment,10.6141,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery charge,efficiency,0.74,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery discharge,efficiency,0.63,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,,,, lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,, lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,, diff --git a/outputs/US/costs_2045.csv b/outputs/US/costs_2045.csv index 19c169ff..6a5458c2 100644 --- a/outputs/US/costs_2045.csv +++ b/outputs/US/costs_2045.csv @@ -4214,11 +4214,11 @@ industrial heat pump medium temperature,efficiency,2.825,per unit,"Danish Energy industrial heat pump medium temperature,investment,720.005,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0,, industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0,, iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0,, -iron-air battery,FOM,1.1808,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery,investment,10.4,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery charge,efficiency,0.74,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery discharge,efficiency,0.63,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, +iron-air battery,FOM,1.1808,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery,investment,10.6141,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery charge,efficiency,0.74,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery discharge,efficiency,0.63,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,,,, lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,, lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,, diff --git a/outputs/US/costs_2050.csv b/outputs/US/costs_2050.csv index cc542137..76f5426e 100644 --- a/outputs/US/costs_2050.csv +++ b/outputs/US/costs_2050.csv @@ -4214,11 +4214,11 @@ industrial heat pump medium temperature,efficiency,2.85,per unit,"Danish Energy industrial heat pump medium temperature,investment,704.9,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0,, industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0,, iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0,, -iron-air battery,FOM,1.1808,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery,investment,10.4,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery charge,efficiency,0.74,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, -iron-air battery discharge,efficiency,0.63,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,, +iron-air battery,FOM,1.1808,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery,investment,10.6141,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery charge,efficiency,0.74,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, +iron-air battery discharge,efficiency,0.63,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,, lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,,,, lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,, lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,, diff --git a/outputs/costs_2020.csv b/outputs/costs_2020.csv index ab101fe5..1997004f 100644 --- a/outputs/costs_2020.csv +++ b/outputs/costs_2020.csv @@ -950,11 +950,11 @@ industrial heat pump medium temperature,efficiency,2.55,per unit,"Danish Energy industrial heat pump medium temperature,investment,877.2984,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0 industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0 iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0 -iron-air battery,FOM,1.0219,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery,investment,23.45,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery charge,efficiency,0.7,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery discharge,efficiency,0.59,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 +iron-air battery,FOM,1.0219,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery,investment,25.1342,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery charge,efficiency,0.7,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery discharge,efficiency,0.59,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,, lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0 lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0 diff --git a/outputs/costs_2025.csv b/outputs/costs_2025.csv index 729814c6..c5c01d96 100644 --- a/outputs/costs_2025.csv +++ b/outputs/costs_2025.csv @@ -950,11 +950,11 @@ industrial heat pump medium temperature,efficiency,2.625,per unit,"Danish Energy industrial heat pump medium temperature,investment,830.775,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0 industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0 iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0 -iron-air battery,FOM,1.0219,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery,investment,23.45,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery charge,efficiency,0.7,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery discharge,efficiency,0.59,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 +iron-air battery,FOM,1.0219,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery,investment,25.1342,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery charge,efficiency,0.7,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery discharge,efficiency,0.59,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,, lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0 lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0 diff --git a/outputs/costs_2030.csv b/outputs/costs_2030.csv index d623a11c..81694585 100644 --- a/outputs/costs_2030.csv +++ b/outputs/costs_2030.csv @@ -950,11 +950,11 @@ industrial heat pump medium temperature,efficiency,2.7,per unit,"Danish Energy A industrial heat pump medium temperature,investment,784.2516,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0 industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0 iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0 -iron-air battery,FOM,1.0,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery,investment,15.61,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery charge,efficiency,0.71,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery discharge,efficiency,0.6,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 +iron-air battery,FOM,1.0,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery,investment,16.7282,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery charge,efficiency,0.71,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery discharge,efficiency,0.6,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,, lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0 lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0 diff --git a/outputs/costs_2035.csv b/outputs/costs_2035.csv index d5099e19..75c6d1da 100644 --- a/outputs/costs_2035.csv +++ b/outputs/costs_2035.csv @@ -950,11 +950,11 @@ industrial heat pump medium temperature,efficiency,2.75,per unit,"Danish Energy industrial heat pump medium temperature,investment,759.6808,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0 industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0 iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0 -iron-air battery,FOM,1.1063,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery,investment,11.79,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery charge,efficiency,0.73,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery discharge,efficiency,0.62,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 +iron-air battery,FOM,1.1063,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery,investment,12.6382,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery charge,efficiency,0.73,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery discharge,efficiency,0.62,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,, lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0 lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0 diff --git a/outputs/costs_2040.csv b/outputs/costs_2040.csv index 4e829332..259ace98 100644 --- a/outputs/costs_2040.csv +++ b/outputs/costs_2040.csv @@ -950,11 +950,11 @@ industrial heat pump medium temperature,efficiency,2.8,per unit,"Danish Energy A industrial heat pump medium temperature,investment,735.11,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0 industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0 iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0 -iron-air battery,FOM,1.1808,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery,investment,10.4,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery charge,efficiency,0.74,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery discharge,efficiency,0.63,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 +iron-air battery,FOM,1.1808,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery,investment,11.1494,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery charge,efficiency,0.74,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery discharge,efficiency,0.63,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,, lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0 lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0 diff --git a/outputs/costs_2045.csv b/outputs/costs_2045.csv index de108515..4776f51c 100644 --- a/outputs/costs_2045.csv +++ b/outputs/costs_2045.csv @@ -950,11 +950,11 @@ industrial heat pump medium temperature,efficiency,2.825,per unit,"Danish Energy industrial heat pump medium temperature,investment,720.005,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0 industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0 iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0 -iron-air battery,FOM,1.1808,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery,investment,10.4,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery charge,efficiency,0.74,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery discharge,efficiency,0.63,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 +iron-air battery,FOM,1.1808,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery,investment,11.1494,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery charge,efficiency,0.74,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery discharge,efficiency,0.63,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,, lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0 lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0 diff --git a/outputs/costs_2050.csv b/outputs/costs_2050.csv index 9c269e46..02166023 100644 --- a/outputs/costs_2050.csv +++ b/outputs/costs_2050.csv @@ -950,11 +950,11 @@ industrial heat pump medium temperature,efficiency,2.85,per unit,"Danish Energy industrial heat pump medium temperature,investment,704.9,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0 industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0 iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0 -iron-air battery,FOM,1.1808,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery,investment,10.4,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery charge,efficiency,0.74,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 -iron-air battery discharge,efficiency,0.63,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0 +iron-air battery,FOM,1.1808,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery,investment,11.1494,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery charge,efficiency,0.74,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 +iron-air battery discharge,efficiency,0.63,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0 lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,, lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0 lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0 diff --git a/test/test_compile_cost_assumptions_usa.py b/test/test_compile_cost_assumptions_usa.py index ebe66af5..543bdbbb 100644 --- a/test/test_compile_cost_assumptions_usa.py +++ b/test/test_compile_cost_assumptions_usa.py @@ -379,13 +379,13 @@ def test_duplicate_fuel_cost(config): @pytest.mark.parametrize( "year, expected", [ - (2020, (90, 7)), - (2025, (90, 7)), - (2030, (90, 7)), - (2035, (90, 7)), - (2040, (90, 7)), - (2045, (90, 7)), - (2050, (90, 7)), + (2020, (91, 7)), + (2025, (91, 7)), + (2030, (91, 7)), + (2035, (91, 7)), + (2040, (91, 7)), + (2045, (91, 7)), + (2050, (91, 7)), ], ) def test_pre_process_manual_input_usa(config, year, expected):