Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathdbus-mqtt-pv-grott.py
executable file
·284 lines (223 loc) · 11.3 KB
/
dbus-mqtt-pv-grott.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
#!/usr/bin/env python
from gi.repository import GLib
import platform
import logging
import sys
import os
import time
import json
import paho.mqtt.client as mqtt
import configparser # for config/ini file
import _thread
# our own packages
sys.path.insert(1, os.path.join(os.path.dirname(__file__), '../ext/velib_python'))
from vedbus import VeDbusService
path_UpdateIndex = '/UpdateIndex'
# get values from config.ini file
config = configparser.ConfigParser()
config.read("%s/config.ini" % (os.path.dirname(os.path.realpath(__file__))))
# MQTT setup
MQTT_broker_address = config['MQTT']['broker_address']
MQTT_topic = config['MQTT']['topic']
MQTT_client_name = "MqttPV"
# set variables
connected = 0
pv_power = 0
pv_current = 0
pv_voltage = 0
pv_forward = 0
pv_L1_power = None
pv_L1_current = None
pv_L1_voltage = None
pv_L1_forward = None
pv_L2_power = None
pv_L2_current = None
pv_L2_voltage = None
pv_L2_forward = None
pv_L3_power = None
pv_L3_current = None
pv_L3_voltage = None
pv_L3_forward = None
# MQTT requests
def on_disconnect(client, userdata, rc):
global connected
print("Client got disconnected")
if rc != 0:
print('Unexpected MQTT disconnection. Will auto-reconnect')
else:
print('rc value:' + str(rc))
try:
print("Trying to reconnect")
client.connect(MQTT_broker_address)
connected = 1
except Exception as e:
logging.exception("Error in retrying to connect with broker")
print("Error in retrying to connect with broker")
connected = 0
print(e)
def on_connect(client, userdata, flags, rc):
global connected
if rc == 0:
print("Connected to MQTT broker!")
connected = 1
client.subscribe(MQTT_topic)
else:
print("Failed to connect, return code %d\n", rc)
def on_message(client, userdata, msg):
try:
# Growatt MIN2500
# {"device": "TCG2A4707E", "time": "2022-11-29T22:51:32", "buffered": "no", "values": {"recortype1": 3000, "recortype2": 3124, "pvstatus": 0, "pvpowerin": 0, "pv1voltage": 0, "pv1current": 0, "pv1watt": 0, "pv2voltage": 0, "pv2current": 0, "pv2watt": 0, "pvpowerout": 0, "pvfrequentie": 0, "pvgridvoltage": 0, "pvgridcurrent": 0, "pvgridpower": 0, "pvgridvoltage2": 0, "pvgridcurrent2": 0, "pvgridpower2": 0, "pvgridvoltage3": 0, "pvgridcurrent3": 0, "pvgridpower3": 0, "totworktime": 42984395, "pvenergytoday": 7, "pvenergytotal": 35229, "epvtotal": 36394, "epv1today": 0, "epv1total": 120, "epv2today": 8, "epv2total": 36274, "pvtemperature": 0, "pvipmtemperature": 111}}
#t = js['time']
#return js.get('values').get('totworktime')
global pv_power, pv_current, pv_voltage, pv_forward, pv_L1_power, pv_L1_current, pv_L1_voltage, pv_L1_forward, pv_L2_power, pv_L2_current, pv_L2_voltage, pv_L2_forward, pv_L3_power, pv_L3_current, pv_L3_voltage, pv_L3_forward
# get JSON from topic
if msg.topic == MQTT_topic:
js = json.loads(msg.payload)
pv_power = float(js['values']['pvpowerout']) / 10
pv_forward = float(js['values']['pvenergytotal']) / 10
# check if L1 and L1 -> power exists
if config['DEFAULT']['pv_line'] == '1':
pv_L1_power = float(js['values']['pvgridpower']) / 10
pv_L1_current = float(js['values']['pvgridcurrent']) / 10
pv_L1_voltage = float(js['values']['pvgridvoltage']) / 10
pv_L1_forward = float(js['values']['pvenergytoday']) / 10
elif config['DEFAULT']['pv_line'] == '2':
pv_L2_power = float(js['values']['pvgridpower']) / 10
pv_L2_current = float(js['values']['pvgridcurrent']) / 10
pv_L2_voltage = float(js['values']['pvgridvoltage']) / 10
pv_L2_forward = float(js['values']['pvenergytoday']) / 10
else:
pv_L3_power = float(js['values']['pvgridpower']) / 10
pv_L3_current = float(js['values']['pvgridcurrent']) / 10
pv_L3_voltage = float(js['values']['pvgridvoltage']) / 10
pv_L3_forward = float(js['values']['pvenergytoday']) / 10
except Exception as e:
logging.exception("Failed to parse MQTT message. (on message function)")
print(e)
print("Failed to parse MQTT message")
class DbusMqttPvService:
def __init__(self, servicename, deviceinstance, paths, productname='MQTT PV', connection='MQTT PV service'):
global config
self._dbusservice = VeDbusService(servicename)
self._paths = paths
logging.debug("%s /DeviceInstance = %d" % (servicename, deviceinstance))
# Create the management objects, as specified in the ccgx dbus-api document
self._dbusservice.add_path('/Mgmt/ProcessName', __file__)
self._dbusservice.add_path('/Mgmt/ProcessVersion', 'Unkown version, and running on Python ' + platform.python_version())
self._dbusservice.add_path('/Mgmt/Connection', connection)
# Create the mandatory objects
self._dbusservice.add_path('/DeviceInstance', deviceinstance)
self._dbusservice.add_path('/ProductId', 0xFFFF) # value used in ac_sensor_bridge.cpp of dbus-cgwacs
self._dbusservice.add_path('/ProductName', productname)
self._dbusservice.add_path('/CustomName', productname)
self._dbusservice.add_path('/FirmwareVersion', 0.1)
self._dbusservice.add_path('/HardwareVersion', 0)
self._dbusservice.add_path('/Connected', 1)
self._dbusservice.add_path('/Latency', None)
self._dbusservice.add_path('/Position', int(config['DEFAULT']['pv_position'])) # normaly only needed for pvinverter
self._dbusservice.add_path('/StatusCode', 0) # Dummy path so VRM detects us as a PV-inverter.
for path, settings in self._paths.items():
self._dbusservice.add_path(
path, settings['initial'], gettextcallback=settings['textformat'], writeable=True, onchangecallback=self._handlechangedvalue
)
GLib.timeout_add(1000, self._update) # pause 1000ms before the next request
def _update(self):
self._dbusservice['/Ac/Power'] = round(pv_power, 2)
self._dbusservice['/Ac/Current'] = round(pv_current, 2)
self._dbusservice['/Ac/Voltage'] = round(pv_voltage, 2)
self._dbusservice['/Ac/Energy/Forward'] = round(pv_forward, 2)
#self._dbusservice['/StatusCode'] = 7
if config['DEFAULT']['pv_line'] == '1' and pv_L1_power != None:
self._dbusservice['/Ac/L1/Power'] = round(pv_L1_power, 2)
self._dbusservice['/Ac/L1/Current'] = round(pv_L1_current, 2)
self._dbusservice['/Ac/L1/Voltage'] = round(pv_L1_voltage, 2)
self._dbusservice['/Ac/L1/Energy/Forward'] = round(pv_L1_forward, 2)
elif config['DEFAULT']['pv_line'] == '2' and pv_L2_power != None:
self._dbusservice['/Ac/L2/Power'] = round(pv_L2_power, 2)
self._dbusservice['/Ac/L2/Current'] = round(pv_L2_current, 2)
self._dbusservice['/Ac/L2/Voltage'] = round(pv_L2_voltage, 2)
self._dbusservice['/Ac/L2/Energy/Forward'] = round(pv_L2_forward, 2)
elif config['DEFAULT']['pv_line'] == '3' and pv_L3_power != None:
self._dbusservice['/Ac/L3/Power'] = round(pv_L3_power, 2)
self._dbusservice['/Ac/L3/Current'] = round(pv_L3_current, 2)
self._dbusservice['/Ac/L3/Voltage'] = round(pv_L3_voltage, 2)
self._dbusservice['/Ac/L3/Energy/Forward'] = round(pv_L3_forward, 2)
logging.info("PV: {:.1f} W - {:.1f} V - {:.1f} A".format(pv_power, pv_voltage, pv_current))
if pv_L1_power:
logging.info("|- L1: {:.1f} W - {:.1f} V - {:.1f} A".format(pv_L1_power, pv_L1_voltage, pv_L1_current))
if pv_L2_power:
logging.info("|- L2: {:.1f} W - {:.1f} V - {:.1f} A".format(pv_L2_power, pv_L2_voltage, pv_L2_current))
if pv_L3_power:
logging.info("|- L3: {:.1f} W - {:.1f} V - {:.1f} A".format(pv_L3_power, pv_L3_voltage, pv_L3_current))
# increment UpdateIndex - to show that new data is available
index = self._dbusservice[path_UpdateIndex] + 1 # increment index
if index > 255: # maximum value of the index
index = 0 # overflow from 255 to 0
self._dbusservice[path_UpdateIndex] = index
return True
def _handlechangedvalue(self, path, value):
logging.debug("someone else updated %s to %s" % (path, value))
return True # accept the change
def main():
logging.basicConfig(level=logging.INFO) # use INFO for less logging, DEBUG for debugging
_thread.daemon = True # allow the program to quit
from dbus.mainloop.glib import DBusGMainLoop
# Have a mainloop, so we can send/receive asynchronous calls to and from dbus
DBusGMainLoop(set_as_default=True)
#formatting
_kwh = lambda p, v: (str(round(v, 2)) + 'kWh')
_a = lambda p, v: (str(round(v, 2)) + 'A')
_w = lambda p, v: (str(round(v, 2)) + 'W')
_v = lambda p, v: (str(round(v, 2)) + 'V')
_n = lambda p, v: (str(round(v, 0)))
paths_dbus = {
'/Ac/Power': {'initial': 0, 'textformat': _w},
'/Ac/Current': {'initial': 0, 'textformat': _a},
'/Ac/Voltage': {'initial': 0, 'textformat': _v},
'/Ac/Energy/Forward': {'initial': None, 'textformat': _kwh},
'/Ac/MaxPower': {'initial': int(config['DEFAULT']['pv_max']), 'textformat': _w},
'/Ac/Position': {'initial': int(config['DEFAULT']['pv_position']), 'textformat': _n},
'/Ac/StatusCode': {'initial': 0, 'textformat': _n},
path_UpdateIndex: {'initial': 0, 'textformat': _n},
}
if config['DEFAULT']['pv_line'] == '1':
paths_dbus.update({
'/Ac/L1/Power': {'initial': 0, 'textformat': _w},
'/Ac/L1/Current': {'initial': 0, 'textformat': _a},
'/Ac/L1/Voltage': {'initial': 0, 'textformat': _v},
'/Ac/L1/Energy/Forward': {'initial': None, 'textformat': _kwh},
})
elif config['DEFAULT']['pv_line'] == '2':
paths_dbus.update({
'/Ac/L2/Power': {'initial': 0, 'textformat': _w},
'/Ac/L2/Current': {'initial': 0, 'textformat': _a},
'/Ac/L2/Voltage': {'initial': 0, 'textformat': _v},
'/Ac/L2/Energy/Forward': {'initial': None, 'textformat': _kwh},
})
elif config['DEFAULT']['pv_line'] == '3':
paths_dbus.update({
'/Ac/L3/Power': {'initial': 0, 'textformat': _w},
'/Ac/L3/Current': {'initial': 0, 'textformat': _a},
'/Ac/L3/Voltage': {'initial': 0, 'textformat': _v},
'/Ac/L3/Energy/Forward': {'initial': None, 'textformat': _kwh},
})
pvac_output = DbusMqttPvService(
servicename='com.victronenergy.pvinverter.mqtt_pv',
deviceinstance=31,
paths=paths_dbus,
productname=config['DEFAULT']['device_name']
)
logging.info('Connected to dbus and switching over to GLib.MainLoop() (= event based)')
mainloop = GLib.MainLoop()
mainloop.run()
# MQTT configuration
client = mqtt.Client(MQTT_client_name) # create new instance
client.on_disconnect = on_disconnect
client.on_connect = on_connect
client.on_message = on_message
client.connect(MQTT_broker_address) # connect to broker
client.loop_start()
# wait to receive first data, else the JSON is empty
time.sleep(5)
if __name__ == "__main__":
main()