-
Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathsnmp.mib
218 lines (159 loc) · 8.85 KB
/
snmp.mib
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
* This is a MIB description for Microchip TCP/IP Stack.
* Anyline starting without '$' is a comment.
* Line starting with $ is a command and first word after $ must be
* a valid command string.
*
* Use mib2bib to compile this file and generate binary BIB file.
*
* v1.0 supports following commands
* $DeclareVar(<oidName>, <dataType>, <oidType>, <access>, <oidString>)
*
* Author Date Comment
* ==========================================================================
* Nilesh Rajbharti 5/21/03 Initial (v1.0)
* Howard Schlunder 9/12/06 Testing with 3.75
* Amit Shirbhate 3/10/09 Snmp Version v2c Updates
*
DeclareVar(<NodeName>, <NodeDataType>, <NodeType>, <NodeAccess>, <NodeOID>)
****************************************************************************
* MIB-2 SYSTEM MIB
****************************************************************************
$DeclareVar(SYS_NAME, ASCII_STRING, SINGLE, READONLY, 43.6.1.2.1.1.5)
$StaticVar(SYS_NAME, Microchip)
$DeclareVar(SYS_DESCR, ASCII_STRING, SINGLE, READONLY, 43.6.1.2.1.1.1)
$StaticVar(SYS_DESCR, PIC)
$DeclareVar(SYS_CONTACT, ASCII_STRING, SINGLE, READONLY, 43.6.1.2.1.1.4)
$StaticVar(SYS_CONTACT, admin)
$DeclareVar(SYS_LOCATION, ASCII_STRING, SINGLE, READONLY, 43.6.1.2.1.1.6)
$StaticVar(SYS_LOCATION, office)
$DeclareVar(SYS_SERVICES, BYTE, SINGLE, READONLY, 43.6.1.2.1.1.7)
$StaticVar(SYS_SERVICES, 7)
$DeclareVar(SYS_UP_TIME, TIME_TICKS, SINGLE, READONLY, 43.6.1.2.1.1.3)
$DynamicVar(SYS_UP_TIME, 250)
$DeclareVar(MICROCHIP, OID, SINGLE, READONLY, 43.6.1.2.1.1.2)
$StaticVar(MICROCHIP, 43.6.1.4.1.17095)
This declaration is must if this agent is going to send traps out.
Application must pass this OID name as one of the parameter when generating
trap. Without a valid AgentID definition, SNMPNotify would fail.
$AgentID(MICROCHIP, 255)
****************************************************************************
* END OF MIB-2 SYSTEM MIB
****************************************************************************
****************************************************************************
* MICROCHIP - MICROCHIP MIB
****************************************************************************
----------------------------------------------------------------------------
- microchip.product
----------------------------------------------------------------------------
$DeclareVar(PRODUCT_NAME, ASCII_STRING, SINGLE, READONLY, 43.6.1.4.1.17095.1.1)
$StaticVar(PRODUCT_NAME, SNMPv3Agent)
$DeclareVar(PRODUCT_VERSION, ASCII_STRING, SINGLE, READONLY, 43.6.1.4.1.17095.1.2)
$StaticVar(PRODUCT_VERSION, v5.31)
$DeclareVar(VERSION_DATE, ASCII_STRING, SINGLE, READONLY, 43.6.1.4.1.17095.1.3)
$StaticVar(VERSION_DATE, Oct 10)
----------------------------------------------------------------------------
- microchip.setup
----------------------------------------------------------------------------
TRAP RECEIVER is table with following format:
TRAP_RECEIVER_ID is index.
-----------------------------------------------------------------------------
TRAP_RECEIVER_ID | TRAP_ENABLED | TRAP_RECEIVER_IP | TRAP_COMMUNITY
-----------------------------------------------------------------------------
0..3 | OFF(0)/ON(0) | X.X.X.X | ASCII_STRING(0..7)
------------------------------------------------------------------------------
$DeclareVar(TRAP_RECEIVER_ID, BYTE, SEQUENCE, READWRITE, 43.6.1.4.1.17095.2.1.1.1)
$DynamicVar(TRAP_RECEIVER_ID, 1)
$SequenceVar(TRAP_RECEIVER_ID, TRAP_RECEIVER_ID)
$DeclareVar(TRAP_RECEIVER_ENABLED, BYTE, SEQUENCE, READWRITE, 43.6.1.4.1.17095.2.1.1.2)
$DynamicVar(TRAP_RECEIVER_ENABLED, 2)
$SequenceVar(TRAP_RECEIVER_ENABLED, TRAP_RECEIVER_ID)
$DeclareVar(TRAP_RECEIVER_IP, IP_ADDRESS, SEQUENCE, READWRITE, 43.6.1.4.1.17095.2.1.1.3)
$DynamicVar(TRAP_RECEIVER_IP, 3)
$SequenceVar(TRAP_RECEIVER_IP, TRAP_RECEIVER_ID)
$DeclareVar(TRAP_COMMUNITY, ASCII_STRING, SEQUENCE, READWRITE, 43.6.1.4.1.17095.2.1.1.4)
$DynamicVar(TRAP_COMMUNITY, 4)
$SequenceVar(TRAP_COMMUNITY, TRAP_RECEIVER_ID)
----------------------------------------------------------------------------
- microchip.control
----------------------------------------------------------------------------
microchip.control.ledD5
$DeclareVar(LED_D5, BYTE, SINGLE, READWRITE, 43.6.1.4.1.17095.3.1)
$DynamicVar(LED_D5, 5)
microchip.control.ledD6
$DeclareVar(LED_D6, BYTE, SINGLE, READWRITE, 43.6.1.4.1.17095.3.2)
$DynamicVar(LED_D6, 6)
microchip.control.pushButton
$DeclareVar(PUSH_BUTTON, BYTE, SINGLE, READONLY, 43.6.1.4.1.17095.3.3)
$DynamicVar(PUSH_BUTTON, 7)
microchip.control.analogPot0
$DeclareVar(ANALOG_POT0, WORD, SINGLE, READONLY, 43.6.1.4.1.17095.3.4)
$DynamicVar(ANALOG_POT0, 8)
microchip.control.lcdDisplay
$DeclareVar(LCD_DISPLAY, ASCII_STRING, SINGLE, READWRITE, 43.6.1.4.1.17095.3.6)
$DynamicVar(LCD_DISPLAY, 10)
****************************************************************************
* snmpFrameworkMIBObjects
****************************************************************************
$DeclareVar(ENGINE_ID, ASCII_STRING, SINGLE, READONLY, 43.6.1.6.3.10.2.1.1)
$DynamicVar(ENGINE_ID, 249)
$DeclareVar(ENGINE_BOOT, DWORD, SINGLE, READONLY, 43.6.1.6.3.10.2.1.2)
$DynamicVar(ENGINE_BOOT, 248)
$DeclareVar(ENGINE_TIME, DWORD, SINGLE, READONLY, 43.6.1.6.3.10.2.1.3)
$DynamicVar(ENGINE_TIME, 247)
$DeclareVar(ENGINE_MAX_MSG, WORD, SINGLE, READONLY, 43.6.1.6.3.10.2.1.4)
$DynamicVar(ENGINE_MAX_MSG, 246)
****************************************************************************
* END OF SNMP FRAMEWORK MIB
****************************************************************************
****************************************************************************
* SNMP-USER-BASED-SM-MIB
****************************************************************************
User configured USM table where USM_INDEX_ID is used as index
$DeclareVar(USM_INDEX_ID, BYTE, SEQUENCE, READONLY, 43.6.1.4.1.17095.4.1.1.1)
$DynamicVar(USM_INDEX_ID, 11)
$SequenceVar(USM_INDEX_ID, USM_INDEX_ID)
$DeclareVar(USER_SECURITY_NAME, ASCII_STRING, SEQUENCE, READWRITE, 43.6.1.4.1.17095.4.1.1.2)
$DynamicVar(USER_SECURITY_NAME, 12)
$SequenceVar(USER_SECURITY_NAME, USM_INDEX_ID)
$DeclareVar(USM_AUTH_PROT, BYTE, SEQUENCE, READWRITE, 43.6.1.4.1.17095.4.1.1.3)
$DynamicVar(USM_AUTH_PROT, 13)
$SequenceVar(USM_AUTH_PROT, USM_INDEX_ID)
$DeclareVar(USM_AUTH_KEY, ASCII_STRING, SEQUENCE, READWRITE, 43.6.1.4.1.17095.4.1.1.4)
$DynamicVar(USM_AUTH_KEY, 14)
$SequenceVar(USM_AUTH_KEY, USM_INDEX_ID)
$DeclareVar(USM_PRIV_PROT, BYTE, SEQUENCE, READWRITE, 43.6.1.4.1.17095.4.1.1.5)
$DynamicVar(USM_PRIV_PROT, 15)
$SequenceVar(USM_PRIV_PROT, USM_INDEX_ID)
$DeclareVar(USM_PRIV_KEY, ASCII_STRING, SEQUENCE, READWRITE, 43.6.1.4.1.17095.4.1.1.6)
$DynamicVar(USM_PRIV_KEY, 16)
$SequenceVar(USM_PRIV_KEY, USM_INDEX_ID)
****************************************************************************
* SNMP-TARGET-MIB
****************************************************************************
User configured USM table where SNMP_TARGET_INDEX_ID is used as index
$DeclareVar(SNMP_TARGET_INDEX_ID, BYTE, SEQUENCE, READONLY, 43.6.1.4.1.17095.5.1.1.1)
$DynamicVar(SNMP_TARGET_INDEX_ID, 17)
$SequenceVar(SNMP_TARGET_INDEX_ID,SNMP_TARGET_INDEX_ID)
$DeclareVar(SNMP_TARGET_MP_MODEL, BYTE, SEQUENCE, READWRITE, 43.6.1.4.1.17095.5.1.1.2)
$DynamicVar(SNMP_TARGET_MP_MODEL, 18)
$SequenceVar(SNMP_TARGET_MP_MODEL, SNMP_TARGET_INDEX_ID)
$DeclareVar(SNMP_TARGET_SECURITY_MODEL, BYTE, SEQUENCE, READWRITE, 43.6.1.4.1.17095.5.1.1.3)
$DynamicVar(SNMP_TARGET_SECURITY_MODEL, 19)
$SequenceVar(SNMP_TARGET_SECURITY_MODEL, SNMP_TARGET_INDEX_ID)
$DeclareVar(SNMP_TARGET_SECURITY_NAME, ASCII_STRING, SEQUENCE, READWRITE, 43.6.1.4.1.17095.5.1.1.4)
$DynamicVar(SNMP_TARGET_SECURITY_NAME, 20)
$SequenceVar(SNMP_TARGET_SECURITY_NAME, SNMP_TARGET_INDEX_ID)
$DeclareVar(SNMP_TARGET_SECURITY_LEVEL, BYTE, SEQUENCE, READWRITE, 43.6.1.4.1.17095.5.1.1.5)
$DynamicVar(SNMP_TARGET_SECURITY_LEVEL, 21)
$SequenceVar(SNMP_TARGET_SECURITY_LEVEL, SNMP_TARGET_INDEX_ID)
****************************************************************************
* END OF USM MIB
****************************************************************************
$DeclareVar(SNMPV3_PVT_VAL, BYTE, SINGLE, READONLY, 43.6.1.4.1.17095.6.1)
$StaticVar(SNMPV3_PVT_VAL, 10)
****************************************************************************
* END OF SNMPV3 PVT MIB
****************************************************************************
****************************************************************************
* END OF MICROCHIP - Demo MIB
****************************************************************************