Find expensive WinUI parsing, layout, rendering, and GC context

winapp run . --profile .\traces\startup --detach

This launches your project and starts a bounded native WinUI 3 ETW recording. Use the returned capture ID with winapp perf status or winapp perf stop. The default recording lasts 30 seconds and allows 512 MiB of raw ETL. Override these with --profile-duration-sec (1-300) and --profile-max-size-mib (1-1024). UI-heavy scenarios such as repeated page navigation can record several MiB per second. If a recording stops with stop reason size-limit before your scenario ends, raise the size limit or shorten the scenario. Without --detach, run continues waiting for the app after recording finishes. Stopping a recording never closes the app. Profiling runs only on this machine. run --profile --on sandbox fails before building or launching; remove --on sandbox to profile locally, or remove --profile to run in Windows Sandbox without recording. Closing the app ends and finalizes its recording immediately, including with --detach; it does not wait for the duration limit. Status reports completed with stop reason target-exited. Retained events remain available for analysis. The final buffered events or loss counters may be unavailable after process exit, so coverage can still be partial. Stop explicitly before closing the app when preserving the final moments is important.

For startup coverage, see Record startup layout. --no-launch cannot be combined with --profile. Existing run restrictions still apply; for example, --debug-output cannot be combined with --detach or --json. Debugger pauses distort elapsed timings, so avoid attaching a debugger while profiling.

Record an existing app

winapp perf start --app MyWinUIApp --output .\traces\scroll
winapp perf mark CAPTURE_ID --name scenario-start
# Navigate and scroll in the app, manually or with verified winapp ui selectors.
# Wait for the intended visible scenario to finish before placing the end marker.
winapp perf mark CAPTURE_ID --name scenario-end
winapp perf stop CAPTURE_ID

Replace CAPTURE_ID with the returned id, and MyWinUIApp with your app. start prints the capture ID and stop command. mark confirms the added marker name, and stop confirms that recording stopped. Warnings remain visible. Add --json when a script or agent needs structured capture state and IDs. start returns after the worker's control channel and provider enablement are ready, not after proving that useful events have been recorded. The recorder does not take the foreground or prevent a separate agent from driving the UI. Use winapp ui inspect --app MyWinUIApp --interactive to discover selectors; see UI automation for navigation and scrolling commands.

For attach captures, --app (or -a) accepts a PID, process name (exact or partial), or window title, using the same matching rules as winapp ui:

winapp perf start --app MyWinUIApp --output .\traces\layout
winapp perf start --app "My App Window" --output .\traces\interaction

Names and titles resolve once to a process. Recording covers that process, not only the selected window. If a process name is ambiguous, use a PID or a more specific window title.

The corresponding limit options are --duration-sec and --max-size-mib. A recording also stops when the target exits or its size limit is reached. Use winapp perf status CAPTURE_ID to check whether a background recording is still running or has ended, including its stop reason and any final errors, without stopping it. stop is repeatable. If a worker disappears, status reports failure rather than success. A later stop attempts cleanup only when the recorded process and ETW session identities still match. Unknown loss remains unknown after recovery.

The output directory must be empty. Keep it until you no longer need the evidence, and move captures only after stopping them.

Record startup layout

winapp run . --profile .\traces\startup --profile-mode elevated --detach --json

By default, run --profile starts recording just after the app launches, so early WinUI initialization, XAML parsing, and first layout can be missed. Profile.StartupCoverage reports post-launch attachment; early startup may be missing. That is fine for scenarios that happen after launch, such as navigation or scrolling.

To record startup, add --profile-mode elevated. Windows shows one administrator approval (UAC) prompt for the recorder; your app still runs unelevated under your account. The recording starts before launch and Profile.StartupCoverage reports recorded from launch (elevated session). Do not add startup delays or replace a generated Main to capture startup.

Choose an empty output directory on a local drive, without symbolic links or junctions in its path. Elevated recording also requires a link-free local path for winapp's control directory. The recorder prevents these directories and their parents from being renamed or redirected until it exits. If a path cannot be secured, recording fails; use the direct directory path or record after launch with --profile-mode attach.

Elevated recording is limited to the launched app's package (packaged apps) or executable name (unpackaged apps), and analysis keeps only the launched process. Other instances of the same app that run during the recording also count toward --profile-max-size-mib. If the UAC prompt is declined, run fails before launching; rerun without --profile-mode elevated to record after launch.

If activation reuses an existing process, coverage is labeled attached-to-existing; startup not recorded. Close that instance before launching when you need its startup.

If an elevated recorder is terminated unexpectedly, its recording keeps running until its size limit, the next elevated recording, or until you stop it from an administrator terminal with logman stop WinApp-Perf-<capture-id> -ets.

Analyze the recording

winapp perf analyze .\traces\scroll --from-marker scenario-start --to-marker scenario-end

The default report starts with process resources, then observed activity on the primary UI thread. It lists the 10 XAML resources with the most parsing time, followed by the detailed operation ranking. The text report skips the parsing-resource section when it is empty. Each activity interval belongs to only one category, so nested layout or parsing is not counted again as framework time. Percentages use the selected range's wall-clock duration, not sampled CPU time. The text summary omits per-operation evidence IDs and count/mean/max/p95 statistics for readability. Add --json to include them, or use a drill-down view for more detail. Its footer shows the returned row count and, when more rows exist, a next-page command with the same range and filters. Coverage details remain in JSON; incomplete evidence still produces a nonzero exit status. All text views omit the repeated interpretation disclaimers; use --json to include the structured limitations field.

Category What it includes
Parsing Timed XAML parsing and component-loading scopes
Layout Template application, measure, arrange, and related timed layout scopes
Render Concrete UI-thread render-walk and frame-submission scopes; the enclosing frame is not counted as rendering
Composition submission Main-device commit and DComp surface-update calls on the selected UI thread; not GPU execution or display latency
Other observed XAML Other timed XAML framework, input, scrolling, virtualization, and initialization work
Image decode/load Timed image work on the selected UI thread; off-thread decode does not contribute
Unclassified The remaining selected-range time, including idle, waits, and uninstrumented work

Without --thread, analysis chooses the thread with the most complete frames in the selected range, breaking ties by observed frame time and then thread ID. If no frame is available, it chooses the thread with the most non-image WinUI activity. Use --thread <id> to override that choice.

The parsing preview reports selected-range time, so a parse that crosses a marker or timestamp boundary is clipped. To page every observed resource, run:

winapp perf analyze .\traces\scroll --view parsing --from-marker scenario-start --to-marker scenario-end

Use narrower views to investigate the overview:

winapp perf analyze .\traces\scroll --view elements --type ItemsStackPanel --sort self
winapp perf analyze .\traces\scroll --view element --id e70 --depth 2
winapp perf analyze .\traces\scroll --view frames --offset 10 --limit 10
winapp perf analyze .\traces\scroll --view hotspots --min-frame-ms 16.67
winapp perf analyze .\traces\scroll --view events --event v123

Replace element and event IDs with IDs from your results.

View What it returns
summary Process resources, primary-UI-thread activity, the 10 hottest parsed resources, then recorded phases and elements ranked by exclusive or self time
parsing Complete pageable XAML resource ranking by observed parsing time
elements Element rankings; --type filters observed type names, and --sort accepts self, inclusive, or count
element One trace-local element and, with --depth, elements observed beneath it during the selected range
frames UI-side frame, render-walk and submission intervals, longest first
hotspots Complete Frame intervals at or above --min-frame-ms, longest first, with dominant direct operations and GC overlap
events Original event names, descriptors and selected payload fields, in time order
calls Instrumented operations, longest first; --family layout restricts the operation family
call One operation and its execution subtree, selected with --id; default depth 2, maximum 4
gc CLR collection lifetimes and runtime suspension episodes, in time order
resources Process CPU counters, private bytes, working set, thread count, and handle count, in time order

All views accept --from-ms and --to-ms. --thread selects the UI thread for summary and parsing, and restricts UI operations or raw events in other applicable views. It does not apply to gc, whose boundaries can cross threads, or process-wide resources. Milliseconds are relative to provider readiness; negative times can occur while the provider set is being enabled. A marker and a millisecond boundary cannot specify the same range end. The events view additionally accepts --provider <guid>, --element <id>, and --event <exact-name-or-evidence-id>.

hotspots defaults --min-frame-ms to 16.67. Thresholding uses each complete frame's full elapsed duration, even when the selected range clips the frame; clippedOverlapMs reports only the selected-range overlap. Each row embeds up to four longest complete direct child operations with their call IDs, families, elapsed/exclusive durations, and evidence IDs. Use a child ID with --view call --id <call-id> for deeper expansion. These are instrumented direct children, not CPU stacks, GPU work, or visual-tree descendants.

JSON queries default to 10 rows and at most 16,384 UTF-8 bytes for the whole response. Use nextOffset with the same immutable query to retrieve the next page. --limit allows 1-100 rows; --max-bytes allows 4,096-1,048,576 bytes. byteBudgetLimited, row projected, and event omittedFields indicate bounded projections. Narrow the query or increase the budget to retrieve more detail. For summary, activity is fixed-size and parsingResources is a top-10 preview; parsingResourcesTotal and parsingResourcesOmitted describe that preview independently of the detailed summary page.

Usable partial results are written to stdout with a nonzero exit status. Text output explains why the results may be incomplete on stderr, such as lost events, undecodable timing payloads, or a time range extending beyond the recording. With --json, stderr contains a structured partial_data error and the reasons are in stdout's coverage.reasons. Do not discard stdout solely because the exit code is nonzero. No usable performance evidence is an error, not a report that the app is fast.

Expand an expensive operation

winapp perf analyze .\traces\scroll --view calls --family layout
winapp perf analyze .\traces\scroll --view call --id c42 --depth 3
winapp perf analyze .\traces\scroll --view call --id c42 --depth 3 --json

Replace c42 with a call ID from your results. Console output indents child operations and shows elapsed/exclusive timings, source information where recorded, boundary status, and evidence IDs. This is an execution tree of instrumented operations, not a sampled CPU stack or the visual tree.

Without explicit time boundaries, call selects the operation's observed start and end. clippedOverlapMs is its overlap with the query range; the full elapsed duration is kept separately. When expansion stops at the depth limit, query the indicated child call to continue.

JSON rows include parent IDs, depth, ancestor IDs, child counts and depthLimited. Follow nextOffset to page the same tree without losing its context. A frame containing a long layout can be expanded into the element operations inside it, rather than treating the entire frame duration as rendering work.

Check GC overlap

winapp perf analyze .\traces\scroll --view gc --from-ms 500 --to-ms 1500
winapp perf analyze .\traces\scroll --view gc --from-marker scenario-start --to-marker scenario-end
winapp perf analyze .\traces\scroll --view gc --sort duration
winapp perf analyze .\traces\scroll --view gc --id gc7

Use a returned GC interval ID in place of gc7 to inspect its boundaries and evidence. New captures request informational CLR GC and suspension events automatically. No extra flag is needed for either perf start or run --profile. Allocation sampling, heap dumps, forced collections, and runtime rundown are not requested.

Collection rows show generation, reason, collection type and start-to-end lifetime. A background collection's lifetime is not a pause. Suspension rows keep the request, fully-suspended, restart-begin and restart-complete boundaries separately. The outer duration includes suspension and resumption transitions; fullySuspendedMs covers suspend-complete through restart-begin. Non-GC reasons, such as debugger suspension, are not attributed to GC. GC rows are chronological unless --sort duration is specified. Duration sorting ranks complete collection and suspension rows by outer elapsed durationMs, longest first; incomplete intervals with unavailable duration are returned last. fullySuspendedMs remains separately reported and is not the sort key.

Call, frame, and hotspot rows include gcOverlap when CLR events were observed. Its duration is the union of complete GC-related suspension intervals overlapping that operation and the selected range. It is not additional child work, not CPU time, and not proof that the native UI thread was blocked throughout that interval. If GC coverage is partial, the observed overlap is a lower bound, not an exact total. Use the referenced intervals and their event evidence to investigate.

gcCoverage distinguishes observed, unsupported, unavailable, not-observed, and not-recorded evidence. A failed optional GC provider does not discard usable XAML data; inspect providerStates and its error. A GC query with no recorded CLR events fails explicitly instead of reporting zero pauses. Native apps may emit no CLR events, and older captures cannot gain GC events that were never recorded.

Disk/file I/O, managed lock contention, JIT/loading, CPU scheduling and GPU activity are not included. Physical disk/file tracing requires a separate system-tracing workflow and its permissions; it is not another event source this private logger can enable. Logical network or file-request duration, where separately recorded, also does not by itself prove UI blocking.

Compare process resource cost

winapp perf analyze .\traces\startup --view resources
winapp perf analyze .\traces\scroll --view resources --from-marker scenario-start --to-marker scenario-end --json

Process counters are collected automatically in both attach and elevated captures, including native C++ apps, without requiring extra elevation. Sampling starts when the recorder binds to the target process, repeats approximately once per second, and takes a final sample when stopping if the process is still alive.

The default analysis includes a processResources summary. Use --view resources for the paged timeline, with the same marker/millisecond bounds, --limit, --offset, and --max-bytes. This view reads capture.json directly, so it also works when a finalized capture has no usable XAML events or ETL files.

The summary shows first, last, and maximum observed private bytes, working set, thread count, and handle count within the selected range. Private bytes measure private committed memory; working set measures resident memory and can include shared pages. These are process costs, not allocation counts or memory attributed to XAML, compositor, or driver components.

Summary user/kernel/total CPU milliseconds are differences between the first and last samples in the selected range, across all target-process threads. The timeline's user/kernel CPU values are cumulative since process creation. firstSampleMs and lastSampleMs identify the actual observed span, relative to recording readiness. CPU can exceed elapsed time when multiple cores work concurrently. No CPU percentage or per-thread/module attribution is inferred.

Counters exclude child processes. Even an elevated startup capture cannot recover counter snapshots from before binding. Sampling can miss brief memory/thread spikes, and process exit can prevent a final sample; observed maxima are not exact lifetime peaks. Range boundaries are not interpolated. With fewer than two samples, interval CPU is unavailable, not zero.

Older captures report not-recorded in the summary and cannot gain counters retroactively. A range without samples reports not-observed. Failed sampling attempts appear as failedSamples and lastError, without discarding the ETW recording. A resource query returns retained samples with a nonzero exit status when sampling failures occurred; keep stdout and inspect coverage.reasons.

Separate XAML work from composition submission

winapp perf analyze .\traces\scroll --view calls --family composition --from-marker scenario-start --to-marker scenario-end --json
winapp perf analyze .\traces\scroll --view events --event DCompDeviceCommit --from-marker scenario-start --to-marker scenario-end --json

CommitMainDevice measures elapsed time inside WinUI's main composition-device commit call. Compare it with layout and render-walk timings; the default report separates Composition submission from Render on the selected UI thread. These scopes can nest, so their inclusive totals must not be added together.

New captures also request optional DirectComposition events:

Evidence What it tells you
DCompBeginDraw Elapsed time entering a surface update; start-event fields identify the resource and update rectangle
DCompEndDraw Elapsed time finishing a surface update
DCompUpdateToken Elapsed time updating the surface token
DCompDeviceCommit A notification containing device/channel IDs and the last committed/confirmed batch IDs; it has no inferred duration

The calls view includes all target-process threads unless you add --thread. Use --view call --id <call-id> to inspect a timed operation and --view events --event <event-id> to inspect its referenced start/end evidence. Resource/device IDs are trace-local identifiers, not XAML elements or UI Automation selectors.

Both attach and elevated captures request the same app-side composition evidence. The query's directCompositionProvider reports whether that optional provider was enabled, unavailable, unconfirmed, or not recorded; text summaries also show its status. If unavailable, inspect its error and retain the XAML results. Missing events are not zero composition cost. Older recordings can reveal CommitMainDevice when the XAML events are already present, but cannot gain DirectComposition events that were never recorded.

These timings include any waits inside the calls, not just CPU execution. Neither a returned commit call nor a confirmed batch establishes when pixels reached the display. This does not record DXGI presents, DWM's cross-process composition work, GPU execution, displayed FPS, or input-to-display latency.

Interpret the evidence

  • Inclusive time includes nested work. Exclusive time subtracts the union of direct child operations. Element self time subtracts nested element work without subtracting the same-object override wrapper twice. Both are elapsed time, including waits and interruptions, not CPU execution time.
  • Mean, maximum and nearest-rank p95 use complete calls wholly inside the selected range. Boundary overlaps are clipped and counted separately.
  • layoutBusyMsByThread is the interval union of observed layout work on each thread. It is not CPU utilization; summing threads is not global wall time.
  • Frame phases are not presented frames or FPS. Input and scrolling events show recorded framework work and state, not proven input-to-display latency. Temporal proximity alone does not prove causation.
  • Independent compositor scrolling may produce little layout activity. Missing layout or realization events do not prove smooth scrolling or broken virtualization. CPU sampling, kernel waits and GPU attribution are not captured.
  • Element IDs and pointers are valid only within this capture. Source, names and parent relationships exist only where emitted; they are not a complete visual tree or a mapping to UI Automation IDs. Attaching after creation often leaves anonymous elements. Re-navigating during capture can improve metadata coverage.
  • coverage describes the selected range/thread and capture-wide collection constraints. Capture-wide decode counts remain visible separately; an error elsewhere is not automatically an error in the selected interval. Optional GC coverage is reported independently of XAML.

Files, privacy, and troubleshooting

capture.json records identity, runtime provenance, limits, markers, process counter samples, actual ETL filenames, and stop/loss information. The standard trace.etl files are the raw evidence. Windows tools such as WPA or PerfView may need manifests matching the recorded WinUI runtime to interpret legacy events.

Offline analysis requires a winapp capture directory, not an arbitrary ETL file. It creates a disposable analysis cache with manifest.json, events.ndjson, calls.ndjson, elements.ndjson, and gc.ndjson. Unchanged captures reuse the cache without decoding ETL again; content fingerprints detect changed inputs. If cache integrity checks fail, remove only that capture's analysis directory and analyze again.

Recording uses the target PID and native XAML, XAML diagnostics, XAML operational, and Controls.Perf providers, plus optional CLR GC and DirectComposition events. Controls.Debug, kernel tracing, CPU sampling, and EventPipe are not enabled. Where Windows rejects a narrower event-ID filter, PID filtering stays enabled and the corresponding providerStates entry has eventIdFilterApplied: false. That fallback can record additional informational GC, composition, or XAML diagnostics data and increase overhead.

Raw ETL and metadata can contain names, source paths, URIs, resource keys, and messages. Keep captures local and review them before sharing. A filtered query does not sanitize the raw files.

Problem Action
No usable events Verify the real WinUI app PID, record again, and exercise navigation or scrolling while recording
Runtime not observed Confirm the target loads Microsoft.UI.Xaml.dll; a launcher, non-WinUI app, or already-exited process is not a supported target
Native access error Use an app running under your own account and inspect the native error; winapp elevates only the startup recorder, and only with run --profile-mode elevated
Unsupported descriptors or payloads Keep the ETL and runtime version for investigation; unsupported events are not decoded using an unrelated installed manifest
Partial tail after app exit Recording is finalized normally; analyze the retained events. For more reliable final-moment coverage, stop recording before closing the app
Loss or file cap Use a shorter focused scenario; target-resident private buffers may be lost at exit
Analysis resource limit Capture a smaller scenario; the report marks incomplete evidence rather than truncating the raw ETL
GC unavailable or not observed Inspect providerStates, managedRuntimes and gcCoverage; preserve XAML results, and do not conclude that no GC occurred
Composition unavailable or not observed Inspect directCompositionProvider and its error; retain XAML evidence and do not infer zero composition or presentation cost