Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

ABL grid only does left front corner #5

Closed
runtpacket opened this issue Mar 2, 2020 · 2 comments
Closed

ABL grid only does left front corner #5

runtpacket opened this issue Mar 2, 2020 · 2 comments

Comments

@runtpacket
Copy link

runtpacket commented Mar 2, 2020

when G29 is issued the ABL probes the grid as expected. But, the grid size it is probing is only approx 30mm X 30mm. i.e. it only probes the front left section of the bed. I am going to try formatting SD and reapplying firmware.

Formatted sd card. Reapplied firmware same result. rolled back to previous firmware I got from you a couple weeks ago.

Video https://www.dropbox.com/s/imeidqh9v62hl9d/VID_20200301_195708.mp4?dl=0

@pmjdebruijn
Copy link
Owner

Note in README.md:

X/Y Microstepping has been increased to 32 (resulting in 160 steps/mm).

Did you verify the X/Y steps/mm are set to 160 (given that they previously would have been 80).

Resetting the firmware to defaults will accomplish this as well. Do keep in mind to reconfigure your Z-Offset again after resetting.

@runtpacket
Copy link
Author

That was it. Sorry my fault.