Notifications
You must be signed in to change notification settings - Fork 316
Description
Printer model
XL5T
Firmware version
6.4.0-alpha
Upgrades and modifications
No response
Printing from...
Octoprint
Describe the bug
After loading the alpha firmware, the printer no longer reports a temperature for the enclosure and instead reports 0C at the bottom, and N/A from the enclosure screen.
My understanding of how it calculates a temperature is via a sensor on the active tool.
How to reproduce
Load alpha firmware on Prusa XL with enclosure with the bottom icons set to show enclosure temperature.
Start print.
Temperature should be displayed as 0C when it would show a temperature on the previous firmware.
Expected behavior
Chamber temperature should display as in 6.2.6.
Files
Sample reported temperature command from octoprint to help debug
Recv: T:215.00/215.00 B:59.92/60.00 C:-19.06/0.00 X0:46.00/36.00 A:82.30/0.00 T0:215.00/215.00 T1:27.00/0.00 T2:26.00/0.00 T3:27.00/0.00 T4:26.00/0.00 T5:6.00/0.00 @:69 B@:0 HBR@:255 @0:69 @1:0 @2:0 @3:0 @4:0 @5:0 B_0_0:45.00/45.00 B_1_0:45.00/45.00 B_2_0:45.00/45.00 B_3_0:45.00/45.00 B_0_1:60.00/60.00 B_1_1:60.00/60.00 B_2_1:59.80/60.00 B_3_1:60.00/60.00 B_0_2:45.00/45.00 B_1_2:59.90/60.00 B_2_2:60.00/60.00 B_3_2:45.00/45.00 B_0_3:35.50/30.00 B_1_3:45.00/45.00 B_2_3:45.00/45.00 B_3_3:35.80/30.00
It appears chamber temperature is negative here?