committed
make admonition about losses expanded by default, will add screenshot of BLM display
1 parent beec8d1 commit 95b8e19

File tree

1 file changed

+6
-3
lines changed

1 file changed

+6
-3
lines changed

docs/guis/multiturn/excitation.md

Lines changed: 6 additions & 3 deletions
Original file line numberDiff line numberDiff line change
@@ -211,18 +211,21 @@ Always ask the experts on shift if unsure about the kick amplitudes to set.
211211

212212
Trigger an acquisition by clicking the yellow ++"Acquire with ACDipole excitation"++ button at the bottom left of the GUI.
213213
The AC Dipole will arm, then kick the beam.
214-
Make sure to have a `BLM Display` application open and to monitor the losses during that time.
215214

216-
Afterwards, a new tab will open at the very top of the GUI to display the BPM measurements, which can be checked: a menu list lets one select any BPM from each beam, and view the recorded bunch centroid turn-by-turn data through the acquisition.
215+
!!! tip "Watch for Losses on Kicks"
216+
Make sure to have a `BLM Display` application open and to monitor the losses right after clicking to acquire.
217+
218+
TODO: insert a picture of the BLM display?
217219

218-
??? info "Losses on Kicks"
219220
Sometimes when increasing the kick amplitude, one will notice large losses.
220221
In this case it is recommended to kick a couple times at this amplitude or just below to see if the losses reduce or are consistent.
221222

222223
Should they reduce the beam might have just needed cleaning and one can increase the kick amplitude further.
223224
Otherwise, stop increasing unless a beam dump is affordable.
224225
Refer to the experts on shift if unsure about the losses, and whether the kick amplitude can be increased further.
225226

227+
After the kick is done, a new tab will open at the very top of the GUI to display the BPM measurements, which can be checked: a menu list lets one select any BPM from each beam, and view the recorded bunch centroid turn-by-turn data through the acquisition.
228+
226229
!!! danger "Do not Kick Both Beams Simultaneously"
227230

228231
Firstly, kicking both beams simultaneously might exceed the losses threshold and lead to a beam dump.

0 commit comments

Comments
 (0)