Skip to content

Conversation

@svenn-t
Copy link
Contributor

@svenn-t svenn-t commented Dec 4, 2025

Simple 5x5x5 test cases for TPSA using lagged and fixed-stress coupling schemes to Flow.

See OPM/opm-simulators#6650 and OPM/opm-common#4846.

PR in draft mode, since both companion PRs are in draft mode.

@alfbr alfbr requested a review from totto82 December 4, 2025 12:54
@alfbr
Copy link
Member

alfbr commented Dec 4, 2025

From my end this looks fine, very much welcome a test case to accompany new functionality! Unfortunately, I am not familiar with the functionality in question, so assigned @totto82 at reviewer. Once he confirms that this is fine functionality wise, we merge.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

2 participants