Growatt Register PDF https://community.symcon.de/uploads/short-url/jFo2xrUpTus03y9fWeYrp0Dbfng.pdf
ModbusSerialConfig 3
ModbusBaudrate 115200
ModBusSend {"DeviceAddress": 1, "FunctionCode": 3, "StartAddress": 0, "Type":"int16", "Count":12}
ModBusSend {"DeviceAddress": 1, "FunctionCode": 6, "StartAddress": 10, "Type":"int16", "Count":1, "Values":[44]}
https://github.com/ClassicDIY/ModbusTool
https://ottelo.jimdofree.com/stromz%C3%A4hler-auslesen-tasmota/
ModBusSlave starten
https://github.com/gthvidsten/open-serial-port-monitor/releases/tag/v1.0.5988.23754
Main Menu -> Configure Module -> TX und RX auf "Serial TX" und "Serial RX" setzen
SerialConfig 3
SerialSend "meinString"
https://github.com/ottelo9/tasmota-sml-images
>D
>B
=>sensor53 r
>M 1
+1,16,m,1,9600,GRW,17,10,01040BBB,01040BCF,01040BD1,01040BEF,01040BEB
1,010404UUuu@i0:10,PV Spannung,V,pvspannung,1
1,010404UUuuUUuu@i1:10,Leistung,W,output,2
1,010404UUuu@i2:100,Netzfrequenz,Hz,ntzfrqnz,3
1,010404UUuuUUuu@i3:10,Heute,k,today,3
1,010404UUuuUUuu@i4:10,Gesamt,kWh,total,2