Skip to content

Conversation

@gkaindl
Copy link

@gkaindl gkaindl commented Apr 9, 2018

Currently, HOMING_FEEDRATE_Z is used as speed to retract the nozzle/z-probe between multiple probing repetitions.

However, if a vibration sensitive Z probe is used (such as a piezo sensor) on a delta with a fast Z homing feedrate, the short motion can well fall within the Z_JERK limit, causing an inadvertent triggering of the z-probe at the end of the move due to the momentum of the extruder. Repetier will then trigger an error because it reports the Z probe as not having properly untriggered after moving to back to the probe rest position.

I'd suggest doing this move at Z_PROBE_SPEED instead, since the slower feed rate doesn't really matter at such short distances, and Cartesian printers have a slow Z max. speed anyway. Alternatively, another setting could be introduced, but I think this is a viable compromise.

@gkaindl gkaindl changed the base branch from master to development April 9, 2018 15:10
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant