#HP MSA 2040 Setup Guide ##Scratch profile
System: <hostname> -> Set System Information
hablkary1-1
Alces Software
rackA1
hpccluster - scratch storage
System -> Rear
Pools
Action -> Add Disk Group
Per disk array, create 1 disk group with the following settings:
Type
Name
<scratch/tierX>-ostX
RAID Level
RAID-6
Chunk size
128KB
Online Initialisation
Add disks 1-10 into the RAID6 pool, and optionally select the hot-spare disk into the SPARE pool. Repeat for each disk array in the group.
RAID6
SPARE
Volumes
Action -> Create Linear Volumes
For each disk pool, create a linear volume with the following settings:
Pool
tier1-ost1
Number of volumes
1
Volume name
tier1-ost1_v0001
Volume size
Enable snapshots
Repeat for each disk pool created